Report Signal Table

This assesslet inserts a table with the selected signals. The Filter section is exactly the same as in the Assesslets - Report Signal Graphic.

Report Signal Table assesslet, "Show initial values" enabled

Report signal table in the report

For arrays of data type boolean, the total result of the array elements is displayed if the array elements had constant values during the test execution. Otherwise, the message says Array signal is not constant.

Contant array and an array with changing element values in the Report Signal table

Show as trace table

Displays a table which shows the time, the name, and the value for the selected signals. When Show as trace table is selected, the options Show state information, Show sub elements, Show initial values are disabled. The specifications done under Sorting are also disabled. Note the maximum 32 lines limit for changing signals.

Report signal table in the report as trace table

Show state information

Activates another column in the signal table showing in which states the signal was recorded.

Show sub elements

Displays all sub-elements of an array or struct.

Array signal in Report Signal Table

Sub elements of constant array and matrix signals are not displayed.

Sorting

Add columns and define their order in the Sorting section. Double-click on the element name to choose the option.

Report signal table (sorting)

The amount of entries per signal in the report is restricted to 32.

Show initial values

Adds a column to the table that shows the initial values specified for a test case. When the initial value differs from the default value set in the Declaration Editor, an asterisk is added to value in the report.

Initial value column in the report

When you open a TPT file created with a TPT version older than 5.0, an assesslet signal table with all local signals will be automatically created in the report. You can check it in the Assesslets view.
To set up the signal table using a script, see Script - Report Signal Table.